free quality report for PLCopenXML exports

Rule reference

55 rules of the open linter. Each page has the question as engineers search for it, a short answer, what the defect does to a running plant, and a bad / fixed code example verified by running the linter.

Turn rules on or off and set severity for your team (Team plan) →

High severity · 23

Typo in a gvl.* global name: why CODESYS does not always complain undeclared-global · Global name typo (gvl.*) ELSIF branch never runs: the previous condition already covers the whole range unreachable-branch · Unreachable IF/ELSIF branch TON in CODESYS never fires: the timer instance is not called every scan uncalled-timer · Uncalled timer/trigger Array index out of bounds in Structured Text: CODESYS does not always catch it array-bounds · Array index out of bounds WHILE TRUE without EXIT in a PLC: why the controller hangs infinite-loop · Infinite loop with no exit Division by zero in Structured Text: how to find it before site start-up div-by-zero · Division by a literal zero CheckDivReal or CheckBounds exists but does not protect: a hollowed-out check broken-implicit-check · Implicit check does not protect Two modules with the same Modbus address in a CODESYS configuration modbus-address-duplicate · Duplicate Modbus address on modules Analog input with no plausibility check: a broken sensor reads as 0 °C heating-ai-no-range-check · Analog input without a plausibility check Division by zero in CFC: a literal 0 wired into DIV cfc-div-zero · CFC: division by a literal zero One channel in a group never gets a field written family-gap · Channel never written: a gap in the family Pump 2's block input is fed with pump 1's signal param-channel-mismatch · Channel parameter fed from another channel Pump never starts: the start command depends on its own feedback self-enable · Command depends on its own feedback TON pause lasts one scan: the timer input is cleared later in the same branch timer-reset-by-own-condition · Timer cleared by its own run condition TOF never switches off: the timer input is re-armed in the same branch timer-rearmed-by-own-branch · Off-delay never expires TOF is only called while its input is high: the off-delay never runs timer-off-delay-in-own-branch · Off-delay is not called when it should be counting Two calls of the same timer in a row with different inputs fb-call-overwritten · A second call to the instance overwrites the first R_TRIG fires only once: the edge detector never sees the input drop edge-lost-in-own-branch · An edge input never sees the drop, so only the first event counts Timer has no PT preset anywhere: the output comes at once fb-preset-missing · The instance has no preset anywhere An alarm can never trip: the condition is always false after substitution always-false-condition · Condition can never be true A wired module input has its sensor type set to Off channel-sensor-off · Sensor type cleared on a wired channel An analog module output is mapped but no signal type is selected channel-output-off · Module output left unconfigured An I/O module excluded from polling and forgotten module-disabled · Module excluded from polling

Medium severity · 22

Integer division in Structured Text drops the fraction int-division · Integer division (lost fraction?) REAL_TO_TIME(x) * 1000 truncates the setpoint: 2.7 s becomes 2 s real-to-time-mul · REAL_TO_TIME(...)*N truncates the setpoint REAL_TO_WORD(x) * N: can the WORD overflow real-to-word-mul · REAL_TO_WORD(...)*N may overflow WORD No POUs for Implicit Checks in a CODESYS project: what it changes missing-implicit-checks · No POUs for implicit checks (runtime guards) A Check function exists in the project but is not active implicit-check-disabled · Check present but not active CODESYS task watchdog disabled: why it is dangerous watchdog-disabled · Task watchdog disabled Timer with PT := T#0S: there is no delay timer-zero-pt · Timer with zero delay (PT := T#0) CASE without ELSE in Structured Text: what happens on an unexpected value case-without-else · CASE without an ELSE branch (no default) Assigning a variable to itself, x := x, in Structured Text self-assignment · Assignment of a variable to itself Empty IF branch or empty loop in Structured Text empty-branch · Empty IF/loop branch One line in a group of similar assignments writes to another channel index-mismatch · Line indexes differently from its group An alarm signal is read but nothing ever writes it signal-without-source · Nothing ever raises this alarm Comparing UINT or WORD with zero: IF x < 0 never runs unsigned-vs-zero · Unsigned compared against zero One write in a series goes to a different exchange buffer write-series-outlier · One write in a series goes to another buffer Two programs write the same cells of an exchange array array-write-overlap · Two POUs write the same array cells A block parameter is taken from another unit's settings param-family-outlier · Parameter fed from another unit's settings An output freezes when no mode branch applies output-stuck-outside-modes · Output freezes when no mode branch applies FOR i := 0 TO n - 1 with an unsigned n: a 65535-iteration loop for-unsigned-minus-one · Loop up to X - 1 with an unsigned X Modbus slave buffer window shifted but its size left unchanged buffer-window-overrun · Buffer window shifted but size unchanged DHW: the heating valve opens when the sensor fails heating-dhw-fault-opens · DHW: valve opens on a sensor fault One variable shown on screen under two different captions visu-two-labels · One variable under two captions The number in an element caption differs from the variable index visu-index-mismatch · Caption number differs from the index

Low severity · 10

Double semicolon ;; in Structured Text: is it an error double-semicolon · Double ;; (empty statement) A POU nobody calls: dead code in a CODESYS project dead-pou · Dead code: a POU nobody calls Single-letter variable names in PLC code: why they hurt naming · Cryptic variable name Magic numbers in PLC code: why move a constant to VAR CONSTANT magic-number · Magic number: a raw constant in code A POU without a single comment: the minimum PLC code needs missing-comments · POU without a single comment PLC routine too long: when to split it into function blocks routine-size · Bloated routine (decomposition candidate) Copy-pasted logic in a PLC program: why duplication is risky copy-paste · Duplicated logic block (copy-paste) Deeply nested IF in PLC code: how to simplify it deep-nesting · Deep IF nesting Unused local variable in a POU unused-local · Unused local variable PLCopen variable naming: x, i, r, t prefixes plcopen-naming · Name off the PLCopen standard

Check your project   Local version on GitHub →